KWX-ATS32A8x2H3C20 Featured

Rate this item
(1 Vote)
10 port 32 Amp, 19" Automatic Transfer Switch 10 port 32 Amp, 19" Automatic Transfer Switch PDUeX KWX Rack ATS with PDU Power Monitoring features and Environmental Monitoring option

Automatic Transfer Switch, 10 ports (8 x lockable C13, 2x C19), 32A - 2 x IEC60309 inputs (3m cables), unit monitored, per outlet ON/OFF switchable, total PDU amps and kWh monitoring, serial, auxiliary and sensor probe connections

The KWX ATS series is a remotely monitored PDU that supports redundant equipment switching (redundant PDU) for non-redundant rack equipment such as routers, servers, switches with single power supply.

KWX Rack mount Automatic Transfer Switches provides total current monitoring, outlet switching like a switched rack PDU and delivers consistent power to any type of single-corded equipment. The KWX ATS utilizes dual input power cords supplying power to the connected load. In the event where the primary power source becomes unavailable, the KWX ATS will flawlessly source power from the secondary source without interrupting critical loads. All occurring events are getting logged; great SNMP controls are giving straight insight and handling ways.

The KWX ATS has built-in network connectivity, which allows remote management via Web, SNMP or Telnet/SSH interfaces, provides ENVIeX environmental sensors probe recognition and has the ability to cascade and control up to four KWX-Serial based PDUs of choice.

KWX ATS enables comprehensive measuring, switching methods when adding up to eight sensor probes per KWX appliance for environmental rack monitoring purposes. KWX devices deliver billing grade measuring accuracy. Results are ranging within 1% variance only. KWX Appliances utilizing trueRMS metering by power factor recognition trough out all connected power sensor based PDUs and its rack monitoring sensor probes.


The device software supports various TCP/IP protocols; including HTTP, HTTPS, SSL, SNMP to monitor the input voltage, total current and optional Temperature/Humidity, smoke  sensor probe. Call a PDUeX sales representative for configuration planning support or to define your solution or interfacing method, at any time.

PDUeX ATS series provide:

- Automatic switching transfer time: 8~16 ms at 230V 50~60Hz
- In the event the "primary" in feed fails, the "secondary" in feed powers all outlets and vice versa.
- Processed when zero-crossing
- Current monitoring and notification
on input switch events by Mail or SNMP Trap
- Alarm for current over threshold and fail-over
- Great SNMP features to set up and monitor a large roll out of ATSs with PDUs (whether passive or active)
- Option : all ENVIeX environmental sensor probes (Temp/Humidity, Smoke, Intrusion..)
- Also available as non-managed/non-network version

Case example: The PDUeX Automatic Transfer Switch utilizes two in feed power sources in your 19"-Rack. From these separate circuits then powers your supply single-power supplied rack devices, e.g. Routers, Modems or small servers with (virtually) dual, redundant power sources. You decide witch primary circuit provides power to the -via PDUeX ATS- connected devices. If you provide battery backup power on one side, you would choose the production power phase as default setting.
In the event the primary source, our production power phase, becomes unavailable for whatever reason, the KWX Automatic Transfer Switch switches to the redundant, battery backed power line (secondary) power line without human intervention. It keeps the connected equipment up and running, before it can physically fall into outage, prevents from operational interference in case of maintenance temporary or unsuspected powering problems with the devices you chose.

The high speed switching is timed to be processed when zero-crossing, thus infeed phases does not need to be synchronised.

PDUeX Automatic Transfer Switch series can be accessed via LAN/WAN and serial interface.
Environmental monitoring: Optionally up to eight sensor probes to measure rack conditions can daisy chained (RS485) per device.
1U or 2U form factor, also available in European socket and plug types combinations (also ask for PDUeX special ATS Outlet styles):
EUsocket big
Dimensions
1U 19" Horizontal W D H = 19" x 214.9 x 44.4 mm
0U Vertical mounted L W D = X x 58 x 44.4 mm
"X" length varies on outlet style and number


Feel free to contact us at customer support and speak a PDU eXpert for your country - at any time!

CALL: +49 (0) 808 3548 9270
For a price list simply mailto: This e-mail address is being protected from spambots. You need JavaScript enabled to view it or visit www.PDU-eXpert.eu/contact

Last modified on Saturday, 09 February 2013 16:11